Reading #287
Back to SearchSerial Number: A22L0061432000848
Reading Summary
Serial NumberA22L0061432000848
Read At2026-07-21T02:58:23.173357+10:00
Device Path/dev/sdb
smartctl Version7.5
Model FamilyIndilinx Barefoot 3 based SSDs
Device ModelOCZ-ARC100
Firmware1.00
Capacity120,034,123,776 bytes [120 GB]
Rotation RateSolid State Device
Form Factor
InterfaceSATA/ATA
ProtocolATA
SATA VersionSATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
ATA VersionATA8-ACS (minor revision not indicated)
S.M.A.R.T. AvailableAvailable - device has SMART capability.
S.M.A.R.T. EnabledEnabled
Health82%
Health StatusPASSED
Temperature ℃
Power On Hours0
Power Cycles1
Host Reads
Host Writes
Data Read0.00 MiB
Data Written0.00 MiB
HDD/SSD Health Summary
Yellow = raw > 0 · Red = VALUE below THRESH or FAILED
Runtime_Bad_Block VALUE 0 WORST 0 THRESH 0 RAW 0 — Reallocated sectors Pwr_Cycle_Ct_Unplanned VALUE 100 WORST 100 THRESH 0 RAW 0 — Unexpected power loss events Runtime_Bad_Block VALUE 0 WORST 0 THRESH 0 RAW 0 — Runtime bad blocks Total_Unc_Read_Failures VALUE 100 WORST 100 THRESH 0 RAW 0 — Pending sectors Remaining_Lifetime_Perc VALUE 82 WORST 82 THRESH 0 RAW 82 — Media wearout indicator
ATA SMART Attributes
| ID | Attribute | Flags | VALUE | WORST | THRESH | Type | Updated | Failed | Raw |
|---|---|---|---|---|---|---|---|---|---|
| 5 | Runtime_Bad_Block | ------ | 0 | 0 | 0 | Old_age | Offline | 0 | |
| 9 | Power_On_Hours | ------ | 100 | 100 | 0 | Old_age | Offline | 0 | |
| 12 | Power_Cycle_Count | ------ | 100 | 100 | 0 | Old_age | Offline | 1 | |
| 171 | Avail_OP_Block_Count | ------ | 100 | 100 | 0 | Old_age | Offline | 45003856 | |
| 174 | Pwr_Cycle_Ct_Unplanned | ------ | 100 | 100 | 0 | Old_age | Offline | 0 | |
| 195 | Total_Prog_Failures | ------ | 100 | 100 | 0 | Old_age | Offline | 0 | |
| 196 | Total_Erase_Failures | ------ | 100 | 100 | 0 | Old_age | Offline | 0 | |
| 197 | Total_Unc_Read_Failures | ------ | 100 | 100 | 0 | Old_age | Offline | 0 | |
| 208 | Average_Erase_Count | ------ | 100 | 100 | 0 | Old_age | Offline | 568 | |
| 210 | SATA_CRC_Error_Count | ------ | 100 | 100 | 0 | Old_age | Offline | 0 | |
| 224 | In_Warranty | ------ | 100 | 100 | 0 | Old_age | Offline | 1 | |
| 233 | Remaining_Lifetime_Perc | ------ | 82 | 82 | 0 | Old_age | Offline | 82 | |
| 241 | Host_Writes_GiB | ------ | 100 | 100 | 0 | Old_age | Offline | 0 | |
| 242 | Host_Reads_GiB | ------ | 100 | 100 | 0 | Old_age | Offline | 0 | |
| 249 | Total_NAND_Prog_Ct_GiB | ------ | 100 | 100 | 0 | Old_age | Offline | 0 |
smartctl plaintext
smartctl 7.5 2025-04-30 r5714 [x86_64-linux-6.18.38-2-cachyos-lts] (local build) Copyright (C) 2002-25, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Family: Indilinx Barefoot 3 based SSDs Device Model: OCZ-ARC100 Serial Number: A22L0061432000848 LU WWN Device Id: 5 e83a97 10000c68a Firmware Version: 1.00 User Capacity: 120,034,123,776 bytes [120 GB] Sector Size: 512 bytes logical/physical Rotation Rate: Solid State Device TRIM Command: Available Device is: In smartctl database 7.5/5706 ATA Version is: ATA8-ACS (minor revision not indicated) SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s) Local Time is: Tue Jul 21 02:58:27 2026 AEST SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x00) Offline data collection activity was never started. Auto Offline Data Collection: Disabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 0) seconds. Offline data collection capabilities: (0x1d) SMART execute Offline immediate. No Auto Offline data collection support. Abort Offline collection upon new command. Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. No Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x00) Error logging NOT supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 0) minutes. Extended self-test routine recommended polling time: ( 0) minutes. SMART Attributes Data Structure revision number: 18 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 5 Runtime_Bad_Block 0x0000 000 000 000 Old_age Offline - 0 9 Power_On_Hours 0x0000 100 100 000 Old_age Offline - 0 12 Power_Cycle_Count 0x0000 100 100 000 Old_age Offline - 1 171 Avail_OP_Block_Count 0x0000 100 100 000 Old_age Offline - 45003856 174 Pwr_Cycle_Ct_Unplanned 0x0000 100 100 000 Old_age Offline - 0 195 Total_Prog_Failures 0x0000 100 100 000 Old_age Offline - 0 196 Total_Erase_Failures 0x0000 100 100 000 Old_age Offline - 0 197 Total_Unc_Read_Failures 0x0000 100 100 000 Old_age Offline - 0 208 Average_Erase_Count 0x0000 100 100 000 Old_age Offline - 568 210 SATA_CRC_Error_Count 0x0000 100 100 000 Old_age Offline - 0 224 In_Warranty 0x0000 100 100 000 Old_age Offline - 1 233 Remaining_Lifetime_Perc 0x0000 082 082 000 Old_age Offline - 82 241 Host_Writes_GiB 0x0000 100 100 000 Old_age Offline - 0 242 Host_Reads_GiB 0x0000 100 100 000 Old_age Offline - 0 249 Total_NAND_Prog_Ct_GiB 0x0000 100 100 000 Old_age Offline - 0 SMART Error Log Version: 1 No Errors Logged Warning! SMART Self-Test Log Structure error: invalid SMART checksum. SMART Self-test log structure revision number 1 No self-tests have been logged. [To run self-tests, use: smartctl -t] Selective Self-tests/Logging not supported The above only provides legacy SMART information - try 'smartctl -x' for more