Reading #434

Back to Search

Serial Number: S36FNX0J600590

Reading Summary

Serial NumberS36FNX0J600590
Read At2026-08-01T13:40:34.775465+10:00
Device Path/dev/sdb
smartctl Version7.5
Model Family
Device ModelSAMSUNG MZVLW512HMJP-000H7
FirmwareCXY70H7Q
Capacity512,110,190,592 [512 GB]
Rotation RateSolid State Device
Form Factor
InterfaceNVMe
ProtocolNVMe
NVMe Version1.2
ATA Version
S.M.A.R.T. Available
S.M.A.R.T. Enabled
Health99%
Health StatusPASSED
Temperature ℃22
Power On Hours2583
Power Cycles1595
Host Reads775945839
Host Writes596045121
Data Read23.06 TiB
Data Written12.44 TiB

smartctl plaintext

smartctl 7.5 2025-04-30 r5714 [x86_64-linux-6.18.40-1-cachyos-lts] (local build)
Copyright (C) 2002-25, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF INFORMATION SECTION ===
Model Number:                       SAMSUNG MZVLW512HMJP-000H7
Serial Number:                      S36FNX0J600590
Firmware Version:                   CXY70H7Q
PCI Vendor/Subsystem ID:            0x144d
IEEE OUI Identifier:                0x002538
Total NVM Capacity:                 512,110,190,592 [512 GB]
Unallocated NVM Capacity:           0
Controller ID:                      2
NVMe Version:                       1.2
Number of Namespaces:               1
Namespace 1 Size/Capacity:          512,110,190,592 [512 GB]
Namespace 1 Utilization:            11,704,152,064 [11.7 GB]
Namespace 1 Formatted LBA Size:     512
Namespace 1 IEEE EUI-64:            002538 b671ba85df
Local Time is:                      Sat Aug  1 13:40:34 2026 AEST
Firmware Updates (0x16):            3 Slots, no Reset required
Optional Admin Commands (0x0007):   Security Format Frmw_DL
Optional NVM Commands (0x001f):     Comp Wr_Unc DS_Mngmt Wr_Zero Sav/Sel_Feat
Log Page Attributes (0x03):         S/H_per_NS Cmd_Eff_Lg
Warning  Comp. Temp. Threshold:     77 Celsius
Critical Comp. Temp. Threshold:     80 Celsius

Supported Power States
St Op     Max   Active     Idle   RL RT WL WT  Ent_Lat  Ex_Lat
 0 +     7.60W       -        -    0  0  0  0        0       0
 1 +     6.00W       -        -    1  1  1  1        0       0
 2 +     5.10W       -        -    2  2  2  2        0       0
 3 -   0.0400W       -        -    3  3  3  3      210    1500
 4 -   0.0050W       -        -    4  4  4  4     2200    6000

Supported LBA Sizes (NSID 0x1)
Id Fmt  Data  Metadt  Rel_Perf
 0 +     512       0         0

=== START OF SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

SMART/Health Information (NVMe Log 0x02, NSID 0xffffffff)
Critical Warning:                   0x00
Temperature:                        22 Celsius
Available Spare:                    100%
Available Spare Threshold:          5%
Percentage Used:                    1%
Data Units Read:                    49,531,318 [25.3 TB]
Data Units Written:                 26,705,174 [13.6 TB]
Host Read Commands:                 775,945,839
Host Write Commands:                596,045,121
Controller Busy Time:               2,639
Power Cycles:                       1,595
Power On Hours:                     2,583
Unsafe Shutdowns:                   58
Media and Data Integrity Errors:    0
Error Information Log Entries:      1,861
Warning  Comp. Temperature Time:    0
Critical Comp. Temperature Time:    0
Temperature Sensor 1:               22 Celsius

Warning: NVMe Get Log truncated to 0x200 bytes, 0x200 bytes zero filled
Error Information (NVMe Log 0x01, 16 of 64 entries)
Num   ErrCount  SQId   CmdId  Status  PELoc          LBA  NSID    VS  Message
  0       1861     0  0x0012  0x4212  0x028            0     -     -  Invalid Log Page
  1       1860     0  0x0018  0x4212  0x028            0     -     -  Invalid Log Page
  2       1859     0  0x001a  0x4004  0x02c            0     0     -  Invalid Field in Command
  3       1858     0  0x0019  0x4004  0x02c            0     0     -  Invalid Field in Command
  4       1857     0  0x0015  0x4212  0x028            0     -     -  Invalid Log Page
  5       1856     0  0x0009  0x4016  0x004            0     1     -  Invalid Namespace or Format
  6       1855     0  0x0040  0x4212  0x028            0     -     -  Invalid Log Page
  7       1854     0  0x001a  0x4004  0x02c            0     0     -  Invalid Field in Command

Self-tests not supported