Reading #470

Back to Search

Serial Number: CYB6N013313206A48

Reading Summary

Serial NumberCYB6N013313206A48
Read At2026-09-10T10:16:53.809382+10:00
Device Path/dev/sdb
smartctl Version7.5
Model Family
Device ModelSK hynix BC711 HFM256GD3JX013N
FirmwareHPS1
Capacity256,060,514,304 [256 GB]
Rotation RateSolid State Device
Form Factor
InterfaceNVMe
ProtocolNVMe
NVMe Version1.3
ATA Version
S.M.A.R.T. Available
S.M.A.R.T. Enabled
Health99%
Health StatusPASSED
Temperature ℃23
Power On Hours24799
Power Cycles313
Host Reads426359508
Host Writes2330082786
Data Read11.14 TiB
Data Written34.81 TiB

smartctl plaintext

smartctl 7.5 2025-04-30 r5714 [x86_64-linux-6.18.48-1-cachyos-lts] (local build)
Copyright (C) 2002-25, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF INFORMATION SECTION ===
Model Number:                       SK hynix BC711 HFM256GD3JX013N
Serial Number:                      CYB6N013313206A48
Firmware Version:                   HPS1
PCI Vendor/Subsystem ID:            0x1c5c
IEEE OUI Identifier:                0xace42e
Total NVM Capacity:                 256,060,514,304 [256 GB]
Unallocated NVM Capacity:           0
Controller ID:                      1
NVMe Version:                       1.3
Number of Namespaces:               1
Namespace 1 Size/Capacity:          256,060,514,304 [256 GB]
Namespace 1 Formatted LBA Size:     512
Namespace 1 IEEE EUI-64:            ace42e 002a88424d
Local Time is:                      Thu Sep 10 10:16:53 2026 AEST
Firmware Updates (0x16):            3 Slots, no Reset required
Optional Admin Commands (0x001f):   Security Format Frmw_DL NS_Mngmt Self_Test
Optional NVM Commands (0x005f):     Comp Wr_Unc DS_Mngmt Wr_Zero Sav/Sel_Feat Timestmp
Log Page Attributes (0x1e):         Cmd_Eff_Lg Ext_Get_Lg Telmtry_Lg Pers_Ev_Lg
Maximum Data Transfer Size:         64 Pages
Warning  Comp. Temp. Threshold:     84 Celsius
Critical Comp. Temp. Threshold:     85 Celsius
Namespace 1 Features (0x02):        NA_Fields

Supported Power States
St Op     Max   Active     Idle   RL RT WL WT  Ent_Lat  Ex_Lat
 0 +   6.3000W       -        -    0  0  0  0        5       5
 1 +   2.4000W       -        -    1  1  1  1       30      30
 2 +   1.9000W       -        -    2  2  2  2      100     100
 3 -   0.0500W       -        -    3  3  3  3     1000    1000
 4 -   0.0040W       -        -    3  3  3  3     1000    9000

Supported LBA Sizes (NSID 0x1)
Id Fmt  Data  Metadt  Rel_Perf
 0 +     512       0         0
 1 -    4096       0         0

=== START OF SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

SMART/Health Information (NVMe Log 0x02, NSID 0xffffffff)
Critical Warning:                   0x00
Temperature:                        23 Celsius
Available Spare:                    100%
Available Spare Threshold:          5%
Percentage Used:                    1%
Data Units Read:                    23,933,426 [12.2 TB]
Data Units Written:                 74,757,618 [38.2 TB]
Host Read Commands:                 426,359,508
Host Write Commands:                2,330,082,786
Controller Busy Time:               2,840
Power Cycles:                       313
Power On Hours:                     24,799
Unsafe Shutdowns:                   71
Media and Data Integrity Errors:    0
Error Information Log Entries:      5
Warning  Comp. Temperature Time:    0
Critical Comp. Temperature Time:    0
Temperature Sensor 1:               23 Celsius
Temperature Sensor 2:               28 Celsius

Warning: NVMe Get Log truncated to 0x200 bytes, 0x200 bytes zero filled
Error Information (NVMe Log 0x01, 16 of 256 entries)
No Errors Logged

Warning: NVMe Get Log truncated to 0x200 bytes, 0x034 bytes zero filled
Self-test Log (NVMe Log 0x06, NSID 0xffffffff)
Self-test status: No self-test in progress
Num  Test_Description  Status                       Power_on_Hours  Failing_LBA  NSID Seg SCT Code
 0   Short             Completed without error                   0            -     -   -   -    -