Reading #776

Back to Search

Serial Number: S340NX0K727978

Reading Summary

Serial NumberS340NX0K727978
Read At2026-10-05T14:00:21.678124+10:00
Device Path/dev/sdb
smartctl Version7.5
Model Family
Device ModelSAMSUNG MZVLW256HEHP-000H1
FirmwareCXB73H1Q
Capacity256,060,514,304 [256 GB]
Rotation RateSolid State Device
Form Factor
InterfaceNVMe
ProtocolNVMe
NVMe Version1.2
ATA Version
S.M.A.R.T. Available
S.M.A.R.T. Enabled
Health94%
Health StatusPASSED
Temperature ℃29
Power On Hours3170
Power Cycles3691
Host Reads1564437814
Host Writes1006039670
Data Read43.21 TiB
Data Written24.65 TiB

smartctl plaintext

smartctl 7.5 2025-04-30 r5714 [x86_64-linux-6.18.55-1-cachyos-lts] (local build)
Copyright (C) 2002-25, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF INFORMATION SECTION ===
Model Number:                       SAMSUNG MZVLW256HEHP-000H1
Serial Number:                      S340NX0K727978
Firmware Version:                   CXB73H1Q
PCI Vendor/Subsystem ID:            0x144d
IEEE OUI Identifier:                0x002538
Total NVM Capacity:                 256,060,514,304 [256 GB]
Unallocated NVM Capacity:           0
Controller ID:                      2
NVMe Version:                       1.2
Number of Namespaces:               1
Namespace 1 Size/Capacity:          256,060,514,304 [256 GB]
Namespace 1 Formatted LBA Size:     512
Namespace 1 IEEE EUI-64:            002538 b781b11b6c
Local Time is:                      Mon Oct  5 14:00:21 2026 AEST
Firmware Updates (0x16):            3 Slots, no Reset required
Optional Admin Commands (0x0017):   Security Format Frmw_DL Self_Test
Optional NVM Commands (0x001f):     Comp Wr_Unc DS_Mngmt Wr_Zero Sav/Sel_Feat
Log Page Attributes (0x03):         S/H_per_NS Cmd_Eff_Lg
Warning  Comp. Temp. Threshold:     68 Celsius
Critical Comp. Temp. Threshold:     71 Celsius

Supported Power States
St Op     Max   Active     Idle   RL RT WL WT  Ent_Lat  Ex_Lat
 0 +     7.60W       -        -    0  0  0  0        0       0
 1 +     6.00W       -        -    1  1  1  1        0       0
 2 +     5.10W       -        -    2  2  2  2        0       0
 3 -   0.0400W       -        -    3  3  3  3      210    1500
 4 -   0.0050W       -        -    4  4  4  4     2200    6000

Supported LBA Sizes (NSID 0x1)
Id Fmt  Data  Metadt  Rel_Perf
 0 +     512       0         0

=== START OF SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

SMART/Health Information (NVMe Log 0x02, NSID 0xffffffff)
Critical Warning:                   0x00
Temperature:                        29 Celsius
Available Spare:                    100%
Available Spare Threshold:          5%
Percentage Used:                    6%
Data Units Read:                    92,792,628 [47.5 TB]
Data Units Written:                 52,937,991 [27.1 TB]
Host Read Commands:                 1,564,437,814
Host Write Commands:                1,006,039,670
Controller Busy Time:               3,312
Power Cycles:                       3,691
Power On Hours:                     3,170
Unsafe Shutdowns:                   212
Media and Data Integrity Errors:    0
Error Information Log Entries:      18,795
Warning  Comp. Temperature Time:    0
Critical Comp. Temperature Time:    0
Temperature Sensor 1:               29 Celsius
Temperature Sensor 2:               34 Celsius

Warning: NVMe Get Log truncated to 0x200 bytes, 0x200 bytes zero filled
Error Information (NVMe Log 0x01, 16 of 64 entries)
Num   ErrCount  SQId   CmdId  Status  PELoc          LBA  NSID    VS  Message
  0      18795     0  0x001d  0x4004  0x028            0     1     -  Invalid Field in Command
  1      18794     0  0x001c  0x4004      -            0     1     -  Invalid Field in Command
  2      18793     0  0x0011  0x4212  0x028            0     -     -  Invalid Log Page
  3      18792     0  0x0081  0x4212  0x028            0     -     -  Invalid Log Page
  4      18791     0  0x0027  0x4004  0x02c            0     0     -  Invalid Field in Command
  5      18790     0  0x0026  0x4004  0x02c            0     0     -  Invalid Field in Command
  6      18789     0  0x0025  0x4004  0x028            0     1     -  Invalid Field in Command
  7      18788     0  0x0024  0x4004      -            0     1     -  Invalid Field in Command

Warning: NVMe Get Log truncated to 0x200 bytes, 0x034 bytes zero filled
Self-test Log (NVMe Log 0x06, NSID 0xffffffff)
Self-test status: No self-test in progress
Num  Test_Description  Status                       Power_on_Hours  Failing_LBA  NSID Seg SCT Code
 0   Short             Completed without error                 918            -     -   -   -    -