Reading #86

Back to Search

Serial Number: TW0WJT509DH000AR03PN

Reading Summary

Serial NumberTW0WJT509DH000AR03PN
Read At2026-07-01T15:24:18.045533+10:00
Device Path/dev/sdb
smartctl Version7.5
Model Family
Device ModelSSSTC CV8-8E256-11 SATA 256GB
FirmwareC28110C
Capacity256,060,514,304 bytes [256 GB]
Rotation RateSolid State Device
Form FactorM.2
InterfaceSATA/ATA
ProtocolATA
SATA VersionSATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
ATA VersionACS-2 (minor revision not indicated)
S.M.A.R.T. AvailableAvailable - device has SMART capability.
S.M.A.R.T. EnabledEnabled
Health100%
Health StatusPASSED
Temperature ℃25
Power On Hours1354
Power Cycles3855
Host Reads
Host Writes
Data Read19.18 MiB
Data Written13.74 MiB

HDD/SSD Health Summary

Yellow = raw > 0 · Red = VALUE below THRESH or FAILED

Reallocated_Sector_Ct  VALUE 100  WORST 100  THRESH 0  RAW 0 — Reallocated sectors
Wear_Leveling_Count  VALUE 100  WORST 100  THRESH 0  RAW 119 — SSD wear level (VALUE = health %)
Reported_Uncorrect  VALUE 100  WORST 100  THRESH 0  RAW 0 — Reported uncorrectable errors
UDMA_CRC_Error_Count  VALUE 100  WORST 100  THRESH 0  RAW 0 — SATA link CRC errors

ATA SMART Attributes

IDAttributeFlagsVALUEWORSTTHRESHTypeUpdatedFailedRaw
5Reallocated_Sector_CtPO----1001000Pre-failAlways0
9Power_On_Hours-O----1001000Old_ageAlways1354
12Power_Cycle_CountPO----1001000Pre-failAlways3855
175Program_Fail_Count_ChipPO----1001000Pre-failAlways0
176Erase_Fail_Count_ChipPO----1001000Pre-failAlways0
177Wear_Leveling_CountPO----1001000Pre-failAlways119
178Used_Rsvd_Blk_Cnt_ChipPO----1001000Pre-failAlways0
179Used_Rsvd_Blk_Cnt_TotPO----1001000Pre-failAlways0
180Unused_Rsvd_Blk_Cnt_TotPO----1001005Pre-failAlways111
181Program_Fail_Cnt_TotalPO----1001000Pre-failAlways0
182Erase_Fail_Count_TotalPO----1001000Pre-failAlways0
187Reported_UncorrectPO----1001000Pre-failAlways0
194Temperature_Celsius-O----1001000Old_ageAlways25
195Hardware_ECC_RecoveredPO----1001000Pre-failAlways0
199UDMA_CRC_Error_CountPO----1001000Pre-failAlways0
238Unknown_AttributePO----95950Pre-failAlways95
241Total_LBAs_WrittenPO----1001000Pre-failAlways14406131464
242Total_LBAs_ReadPO----1001000Pre-failAlways20109858272

smartctl plaintext

smartctl 7.5 2025-04-30 r5714 [x86_64-linux-7.1.2-3-cachyos] (local build)
Copyright (C) 2002-25, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF INFORMATION SECTION ===
Device Model:     SSSTC CV8-8E256-11 SATA 256GB
Serial Number:    TW0WJT509DH000AR03PN
LU WWN Device Id: 5 38f601 6101b817b
Firmware Version: C28110C
User Capacity:    256,060,514,304 bytes [256 GB]
Sector Size:      512 bytes logical/physical
Rotation Rate:    Solid State Device
Form Factor:      M.2
TRIM Command:     Available, deterministic, zeroed
Device is:        Not in smartctl database 7.5/5706
ATA Version is:   ACS-2 (minor revision not indicated)
SATA Version is:  SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is:    Wed Jul  1 15:24:26 2026 AEST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART Status not supported: Incomplete response, ATA output registers missing
SMART overall-health self-assessment test result: PASSED
Warning: This result is based on an Attribute check.

General SMART Values:
Offline data collection status:  (0x02)	Offline data collection activity
					was completed without error.
					Auto Offline Data Collection: Disabled.
Self-test execution status:      (   0)	The previous self-test routine completed
					without error or no self-test has ever 
					been run.
Total time to complete Offline 
data collection: 		(    2) seconds.
Offline data collection
capabilities: 			 (0x11) SMART execute Offline immediate.
					No Auto Offline data collection support.
					Suspend Offline collection upon new
					command.
					No Offline surface scan supported.
					Self-test supported.
					No Conveyance Self-test supported.
					No Selective Self-test supported.
SMART capabilities:            (0x0003)	Saves SMART data before entering
					power-saving mode.
					Supports SMART auto save timer.
Error logging capability:        (0x01)	Error logging supported.
					General Purpose Logging supported.
Short self-test routine 
recommended polling time: 	 (   1) minutes.
Extended self-test routine
recommended polling time: 	 (   8) minutes.
SCT capabilities: 	       (0x003d)	SCT Status supported.
					SCT Error Recovery Control supported.
					SCT Feature Control supported.
					SCT Data Table supported.

SMART Attributes Data Structure revision number: 1
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
  5 Reallocated_Sector_Ct   0x0003   100   100   000    Pre-fail  Always       -       0
  9 Power_On_Hours          0x0002   100   100   000    Old_age   Always       -       1354
 12 Power_Cycle_Count       0x0003   100   100   000    Pre-fail  Always       -       3855
175 Program_Fail_Count_Chip 0x0003   100   100   000    Pre-fail  Always       -       0
176 Erase_Fail_Count_Chip   0x0003   100   100   000    Pre-fail  Always       -       0
177 Wear_Leveling_Count     0x0003   100   100   000    Pre-fail  Always       -       119
178 Used_Rsvd_Blk_Cnt_Chip  0x0003   100   100   000    Pre-fail  Always       -       0
179 Used_Rsvd_Blk_Cnt_Tot   0x0003   100   100   000    Pre-fail  Always       -       0
180 Unused_Rsvd_Blk_Cnt_Tot 0x0003   100   100   005    Pre-fail  Always       -       111
181 Program_Fail_Cnt_Total  0x0003   100   100   000    Pre-fail  Always       -       0
182 Erase_Fail_Count_Total  0x0003   100   100   000    Pre-fail  Always       -       0
187 Reported_Uncorrect      0x0003   100   100   000    Pre-fail  Always       -       0
194 Temperature_Celsius     0x0002   100   100   000    Old_age   Always       -       25
195 Hardware_ECC_Recovered  0x0003   100   100   000    Pre-fail  Always       -       0
199 UDMA_CRC_Error_Count    0x0003   100   100   000    Pre-fail  Always       -       0
238 Unknown_Attribute       0x0003   095   095   000    Pre-fail  Always       -       95
241 Total_LBAs_Written      0x0003   100   100   000    Pre-fail  Always       -       14406131464
242 Total_LBAs_Read         0x0003   100   100   000    Pre-fail  Always       -       20109858272

SMART Error Log Version: 1
No Errors Logged

SMART Self-test log structure revision number 1
Num  Test_Description    Status                  Remaining  LifeTime(hours)  LBA_of_first_error
# 1  Extended offline    Completed without error       00%       201         -
# 2  Short offline       Completed without error       00%       201         -
# 3  Short offline       Completed without error       00%         0         -

Selective Self-tests/Logging not supported

The above only provides legacy SMART information - try 'smartctl -x' for more