Reading #93

Back to Search

Serial Number: FY9CN05261280CT39

Reading Summary

Serial NumberFY9CN05261280CT39
Read At2026-07-01T17:47:01.368987+10:00
Device Path/dev/sdb
smartctl Version7.5
Model Family
Device ModelSK hynix BC501 HFM256GDJTNG-8310A
Firmware80002C00
Capacity256,060,514,304 [256 GB]
Rotation RateSolid State Device
Form Factor
InterfaceNVMe
ProtocolNVMe
NVMe Version1.2.1
ATA Version
S.M.A.R.T. Available
S.M.A.R.T. Enabled
Health0%
Health StatusFAILED!
Temperature ℃40
Power On Hours2736
Power Cycles3874
Host Reads1284715896
Host Writes526961909
Data Read30.47 TiB
Data Written13.44 TiB

smartctl plaintext

smartctl 7.5 2025-04-30 r5714 [x86_64-linux-7.1.2-3-cachyos] (local build)
Copyright (C) 2002-25, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF INFORMATION SECTION ===
Model Number:                       SK hynix BC501 HFM256GDJTNG-8310A
Serial Number:                      FY9CN05261280CT39
Firmware Version:                   80002C00
PCI Vendor/Subsystem ID:            0x1c5c
IEEE OUI Identifier:                0xace42e
Controller ID:                      1
NVMe Version:                       1.2.1
Number of Namespaces:               1
Namespace 1 Size/Capacity:          256,060,514,304 [256 GB]
Namespace 1 Formatted LBA Size:     512
Namespace 1 IEEE EUI-64:            ace42e 009a35e9ff
Local Time is:                      Wed Jul  1 17:47:10 2026 AEST
Firmware Updates (0x16):            3 Slots, no Reset required
Optional Admin Commands (0x0017):   Security Format Frmw_DL Self_Test
Optional NVM Commands (0x0016):     Wr_Unc DS_Mngmt Sav/Sel_Feat
Log Page Attributes (0x02):         Cmd_Eff_Lg
Maximum Data Transfer Size:         64 Pages
Warning  Comp. Temp. Threshold:     81 Celsius
Critical Comp. Temp. Threshold:     82 Celsius
Namespace 1 Features (0x02):        NA_Fields

Supported Power States
St Op     Max   Active     Idle   RL RT WL WT  Ent_Lat  Ex_Lat
 0 +   3.5000W       -        -    0  0  0  0        5       5
 1 +   2.4000W       -        -    1  1  1  1       30      30
 2 +   1.9000W       -        -    2  2  2  2      100     100
 3 -   0.0350W       -        -    3  3  3  3     1000    1000
 4 -   0.0050W       -        -    3  3  3  3     1000    5000

Supported LBA Sizes (NSID 0x1)
Id Fmt  Data  Metadt  Rel_Perf
 0 +     512       0         0
 1 -    4096       0         0

=== START OF SMART DATA SECTION ===
SMART overall-health self-assessment test result: FAILED!
- NVM subsystem reliability has been degraded

SMART/Health Information (NVMe Log 0x02, NSID 0xffffffff)
Critical Warning:                   0x04
Temperature:                        40 Celsius
Available Spare:                    100%
Available Spare Threshold:          5%
Percentage Used:                    105%
Data Units Read:                    65,434,232 [33.5 TB]
Data Units Written:                 28,857,592 [14.7 TB]
Host Read Commands:                 1,284,715,896
Host Write Commands:                526,961,909
Controller Busy Time:               8,240
Power Cycles:                       3,874
Power On Hours:                     2,736
Unsafe Shutdowns:                   117
Media and Data Integrity Errors:    0
Error Information Log Entries:      0
Warning  Comp. Temperature Time:    0
Critical Comp. Temperature Time:    0
Temperature Sensor 1:               40 Celsius
Temperature Sensor 2:               41 Celsius

Warning: NVMe Get Log truncated to 0x200 bytes, 0x200 bytes zero filled
Error Information (NVMe Log 0x01, 16 of 256 entries)
No Errors Logged

Warning: NVMe Get Log truncated to 0x200 bytes, 0x034 bytes zero filled
Self-test Log (NVMe Log 0x06, NSID 0xffffffff)
Self-test status: No self-test in progress
No Self-tests Logged